Paga 50€ y navega sin aceptar el consentimiento en este sitio durante 1 año.
Si ya tienes un código introducelo a continuación para validarlo.
EIZO
DICOM Part 14 Compliant
To ensure the most accurate and consistent shadings possible, EIZO carefully measures and sets every grayscale tones on the production line to produce a monitor compliant with DICOM Part 14.
Brightness Stabilization
At startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level. In addition, a sensor measures the backlight brightness and compensates for brightness fluctuations caused by the ambient temperature and the passage of time.
This brightness stabilization function is EIZO patented technology (Japan patent numbers 3171808 and 3193315, US patent number 6188380).
Simplified Calibration
When the self-diagnosis function with the bundled RadiCS LE quality control software detects a change in luminance, a warning icon appears on the desktop taskbar enabling prompt detection and correction. Furthermore, the self-calibration function performs simplified calibration compliant with the DICOM Part 14 standard to correct the grayscale tones and brightness of the monitor. This reduces the time spent administering to the monitor.
Calibration Mode Selection
Selectable with the front panel buttons, the CAL Switch function allows for various calibration modes of different modalities such as CR, CT, and endoscope images. Furthermore, auto mode settings can be made with the Auto CAL Switch function.
Backlight Saver with Screen Saver
With ScreenManager Pro for Medical utility software installed, the Backlight Saver function turns off the monitor’s backlight when the screen saver is activated, and turns it on again when the computer comes out of screen saver mode. This function helps to reduce power consumption when the monitor is used for a prolonged period of time.
Backlight Saver with Viewer Application
By setting the Backlight Saver function to operate with viewer application, the monitor’s backlight is on while the viewer is being used and the backlight is off while the viewer is not being used.
Height Adjustable Stand
The height and tilt adjustable stand offers added flexibility and viewing comfort. 90° pivot for portrait mode gives you versatility with images or applications requiring more vertical viewing space.
Medical Standards
Meets the strictest medical, safety and EMC emissions standards including TÜV/GM, UL60601-1, CE, CB, CSA C22.2 No.601-1, VCCI, FCC, and FDA 510(k).
More Precise Calibration with UX1 Sensor
By using the UX1 sensor (sold separately) with the bundled RadiCS LE software, more precise calibration compliant with the DICOM Part 14 standard can be performed.
Clip-On Swing Sensor
Easy calibration compliant with the DICOM Part 14 standard can be performed with the Clip-On Swing Sensor G2 (sold separately). Once attached to the top of the monitor, it can remain in place and is ready for use. This saves the time and trouble of attaching and removing it when performing QC tasks.
Monitor Quality Control Standards Compliance
Quality control tool RadiCS UX1 (sold separately) enables you to perform basic quality checks necessary for clinical review monitors. In addition, high-performance calibration compliant with the DICOM Part 14 standard corrects the fluctuation in monitor quality.
Centralized Management of All Monitors
RadiNET Pro (sold separately) enables centralized management of calibration tasks, history data of multiple RadiCS clients via a network, and remote QC functions.
Presence Sensor for Convenience
The presence sensor on the front of the Clip-On Swing Sensor G2 determines whether to start QC tasks such as calibrations automatically at scheduled times. If the user is working, the QC task stays in stand-by mode, and when the user is away from the monitor the task is performed.
Presence Sensor for Power Savings
The presence sensor feature unites convenience with savings by ensuring that the monitor conserves power when it is not in use. The presence sensor prompts the monitor to switch to power save mode when it detects the user away from the monitor, and then resume normal operation when the user returns.
Release date: 2011-05-19.
1 VGA input
Power | |
---|---|
AC input frequency: | 50 - 60 Hz |
AC input voltage: | 100 - 240 V |
Power consumption (PowerSave): | 0.8 W |
Power consumption (typical): | 43 W |
Display | |
Digital vertical frequency: | 59 - 61 Hz |
Digital horizontal frequency: | 31 - 64 kHz |
Viewable size diagonal: | 48.1 cm |
Viewable size, vertical: | 30.1 cm |
Viewable size, horizontal: | 37.6 cm |
Vertical scan range: | 50 - 75 Hz |
Horizontal scan range: | 24.8 - 80 kHz |
Pixel pitch: | 0.294 x 0.294 mm |
3D: | No |
Viewing angle, vertical: | 178° |
Viewing angle, horizontal: | 178° |
Aspect ratio: | 5:4 |
Supported graphics resolutions: | 1280 x 1024 (SXGA) |
Response time: | 8 ms (PC screens with 8 milliseconds response ) |
Display brightness (typical): | 300 cd/m² |
Display number of colours: | 16.78 million colours |
Contrast ratio (typical): | 2000:1 |
HD type: | Not supported |
Native aspect ratio: | 5:4 (PC displays with a 5:4 aspect ratio ) |
Display resolution: | 1280 x 1024 pixels |
Display diagonal: | 48.3 cm (19") |
Ports & interfaces | |
USB hub version: | 2.0 |
AC (power) in: | Yes |
HDCP: | No |
DVI-D ports quantity: | 1 |
VGA (D-Sub) ports quantity: | 1 |
USB Type-A downstream ports quantity: | 1 |
Ergonomics | |
Plug and Play: | Yes |
Tilt angle range: | 0 - 30° |
Swivel angle range: | 0 - 35° |
Cable lock slot: | No |
Thin Client | |
Thin client installed: | No |
Other features | |
Certification: | CE, TUV, UL, CB, VCCI-B, FCC-B, FDA, EIZO, RoHS |
TV tuner integrated: | No |
Design | |
Product colour: | Black |
Multimedia | |
Built-in camera: | No |
Built-in speaker(s): | No |
Packaging content | |
Manual: | Yes |